Experiment Information Collection Form – PCI (Plate Impact Experiment) Experiment Information Collection Form - PCI Plate Impact Experiment Information Collection Form - PCI Plate Impact Step 1 of 3 33% Experiment Title Experiment Start Date Month Day Year Experiment Stop Date Month Day Year Lead Experimenter First Last Lead Experimenter Institution Lead Experimenter Email Additional Experimenters (Name, Institution, Email)Scientific ObjectiveNumber of experiments required to achieve scientific objectivePlease enter a number from 1 to 100.List of Material(s) and Equipment X-ray Configuration: white beam ~ 2 mm vertical, 3 mm horizontalUndulator U14 (Standard) U23 (Describe desired configuration) U23Detector ConfigurationCameras (configuration change ~3 hours)2 to 8 total cameras where each camera can be either a 2048 or 1024i PI-Max 4. 8x 2048 cameras, 8 frames (standard) 8x 1024i cameras, 16 frames Other Magnification (FOV) (change ~1 hour)FOV of 1024 is square where the value listed is a side. FOV of 2048 is circular where the value is approx. the radius. 5x: (1024i) 2.5mm x 2.5mm (2048f) 2.5mm x 3.5mm 7.5x (1024i) 1.7mm x 1.7mm, (2048f) 2.5mm x 3.2mm 10x (1024i) 1.3mm x 1.3mm, (2048f) 2.4mm x 2.4mm Scintillator (change ~2 hours) LYSO (standard) LaBr3 Imaging GeometryGun Angle 0˚ (standard) Other Detector Distance 1 Meter (standard) Other Target RotationIs target rotation about the barrel axis needed? ±10° range of motion (installation time ~1 hour) Yes No Timing TriggerTiming Trigger (1.2 μsec from trigger to 1st frame) TOBB (trigger at 50% transmission) PZT (must fully contact within impactor radius) VelocimetryVISAR (1 probe) - Select two:Available VPFs (m/s/fringe) 72 95 181 308 458 945 PDV: Number of ProbesPDV Homodyne Heterodyne Reference Beam Frequency Shift +6 GHz (standard) Other Other: -1 GHz to +8 GHz)User-Supplied ProbesIf supplying own probes, please describe.Previous VisitRelevant details from last DCS visit: Target and Configuration Detail (.doc, .pdf, .jpeg, .png, or .tif)Any additional files can be emailed to dcs.admin@wsu.edu.Please provide a drawing of experimental configuration that includes sample assembly, x-rays to gun angle, detector plane, detector distance and the desired field of view. Drop files here or Select files Max. file size: 146 MB. Please provide a detailed drawing(s) of the target assembly, identifying the various target components and materials used. Include any non-standard details or unusual requests in the diagram. Include any relevant distances/indicators to locate the sample position while aligning the sample using x-rays, for example sample edges/thickness and their distances from target plate/spacers). Drop files here or Select files Max. file size: 146 MB. ShippingPlease review Shipping Requirements.Are you shipping materials in advance of your arrival date? Yes (Provide shipment tracking numbers to dcs.admin@wsu.edu) No Undecided Is your shipment greater than 50 lbs? Yes No Does your shipment contain hazardous materials? Yes No PublicationsReview publication requirements for all work conducted at the DCS. Users are expected to publish results in peer-reviewed journals within a reasonable period (~1 year) after scheduled experiment time.Anticipated timeline for publishing results from your upcoming DCS experiments: Δ